Standard configuration |
|
|
Application |
Indoor. 16-hr operation daily |
|
H(m) |
≤7.2(6) |
|
Inclination (°) |
30(35) |
|
Step width (mm) |
600/800/1000 |
|
Horizontal steps |
2/2 3/3(Only for 30°) |
|
Speed(m/s) |
0.5 |
|
Capacity (per./h) |
4500/6750/9000 |
|
Main power |
380V/50Hz/3P |
|
Balustrade |
Tempered glass(10mm) |
|
Handrail bracket |
Stainless steel |
|
Handrail |
Black |
|
Balustrade height (mm) |
900 |
|
Inner & outer decking |
Hairline St.St. |
|
Skirting |
Wear resistant coating steel sheet |
|
Step |
Stainless steel |
|
Landing plate |
Stainless steel (anti-sliding) |
|
illumination |
lighting under upper & lower landing steps |
|
Indicator |
Failure code indicator on control cabinet |
|
Operation |
Emergency stop buttonKey switchInspection operation |
|
|
|
|
Optional configuration |
|
|
|
|
Different components with individual performance and multi-functional devices ensure our escalator and moving walk can meet various customer demands. |
|
|
|
|
Application |
Semi-outdoor/outdoor. 16-hr operation daily |
|
Handrail bracket |
Aluminum profile |
|
Handrail |
Green, red, blue, yellow |
|
Balustrade height |
1000mm |
|
illumination |
Skirting lighting |
|
Comb lighting |
|
Monitor |
Handrail speed monitor |
|
Handrail break monitor |
|
Indicator |
Indicator on outer decking |
|
Direction indicator |
Running direction indicator on outer decking |
|
Step(escalator) |
One-piece aluminum |
|
Skirting |
Hairline St.St. |
|
Landing plate |
Aluminum alloy (anti-sliding) |
|
Energy control |
VVVF |
|
Lubrication |
Automatic lubrication / electric lubrication |
|
External cladding |
Hairline St.St. / Painted steel /Glass/Mirror st.st. |
|
|
|
|
Safety devices |
|
|
|
|
|
Static electricity protection of step (pallet) |
Eliminate static electricity raised from running of the steps (pallets). |
standard |
Static electricity protection of handrail |
Eliminate static electricity raised from running of the handrail. |
standard |
Emergency stop button on entrance |
Push the emergency stop button to stop the escalator (moving walk) against emergency raise. |
standard |
Handrail entry safety protection |
Protection against risk of other objects being jammed into handrail entry. |
standard |
Over speed protection |
Protection against risk of speed being over 20% of rated speed. |
standard |
Under speed protection |
Protection against risk of speed being less than 20% of rated speed. |
standard |
Unintentional reversal protection |
Protection against risk of unintentional reversal of the direction of travel. |
standard |
Phase failure protection |
Protection against risk of phase failure. |
standard |
Short circuit protection |
Protection against risk of short circuit. |
standard |
Over-load protection |
Protection against risk of motor continually over load. |
standard |
Step(pallet)sagging protection |
Protection against risk of steps (pallets) being breakage and sagging. |
standard |
Step(pallet)chainssafety protection |
Protection against risk of step (pallets) chains being breakage of undue elongation. |
standard |
Comb safety guard |
Protection against risk of foreign objects being trapped at the point where the step (pallet) enters the comb. |
standard |
Inspection socket |
To provide voltage to inspect or maintain. |
standard |
Machine room guard |
One safety plate separates machine room from movable parts such as step to protect service personnel. |
standard |
Emergency stop button oncontrol cabinet |
Push the emergency stop button to stop the escalator (moving walk) against emergency raise when inspection and maintaining. |
standard |
Auxiliary brake |
Auxiliary brake will act and stop the escalator (moving walk) in case of main drive chains breakage or the steps (pallets) or handrail changing from present direction of motion. |
Optional |
Handrail guard |
Protection against risk of speed change and breakage of handrail. |
Optional |
Skirting guard |
Protection against risk of foreign objects being jammed into clearance between steps (pallets) and skirting. |
Optional |
Main drive chains safety protection |
Protection against risk of drive chains being breakage or undue elongation. |
Optional |
Skirting brush |
Brushes on skirting to enhance the passenger's safety. |
Optional |